The Senior

The DALUM CO2 Recovery Plant model Senior, is designed for craft breweries with a production greater than 25.000 hL/yr. The Senior is equipped with a DALUM compressor with a theoretical compressor displacement of 30 kg/h, putting out 24kg LCO2 hour.

Capacity: The Senior model is specifically designed for breweries with a production ranging between 25,000 – 50,000 hL/yr, assuming an alcohol content of 5%.

TECHNICAL DATA
Model Senior.
Capacity Theoretical compressor displacement 0-30 kg CO2 feed gas per hour. Estimated liquid output 0-24 kg CO2 per hour.
Purity 99.980%-99.995% CO2 purity depending on feed.
CO2 supply pressure Minimum 0,2 bar from fermenter.
Feed gas purity Minimum 96% CO2, maximum 0,6% oxygen from fermentation.
Room temperature Minimum 5°C and maximum 40°C.
UTILITY DATA
Electricity 3x400V +N+P, 50 Hz, 16 Amps fuses, 5 kW. Delta T minimum 1.5 bar.
Cooling media -5 to 0°C, flow 0-30 l/min or max 2.5 kW (0.6 kW compressor) No oil or calcium in coolant required.
Water 0-30 l/hour
Drainage 0-30 L/hour.
FEATURES
Dimensions LxWxH: 1x1x4 meters and 1x2x4 including foam trap.
Noise level App. 65 dB(A).
Materials Stainless steel (exclusive motor, gearboxes, control cabinet) and selected electrical valves in brass.
Controls PLC w/ color touchscreen and fully automatic operation. Remote access to live dashboard from pc and mobile devices.
Components As per DALUM's best choice.
Covers/Cladding Optional – recommended if module is placed in fermentation area with spraying water and cleaning agents.
PED-code The CO2 module is outside PED and ASME regulation for site inspection. No approval needed.
Documentation The equipment is delivered CE marked and with available online manuals, videos and documentation for use and maintenance.