Description
Used on the Dalum compressor
| House form | Metric construction form |
| The building form of the house | Standard construction form |
| Thread size | M18 x 1 |
| Diameter | Ø 18 mm |
| Detection distance S n | 8 mm |
| Guaranteed detection distance S a | 6,48 mm |
| Installation in metal | Partially shielded 1) |
| Switching frequency | 1.000 Hz |
| Connection method | Connector M12, 4-pin 2) |
| Transistor output | PNP |
| Output function | Antivalent |
| Electrical design | DC 4 leader |
| Enclosure class | IP68 3)
IP69K 4) |
| Special features | Resistant to coolants/lubricants, IO-Link, Temperature range |
| Special applications | Coolants and lubricants area, Mobile construction machines, Harsh operating conditions |
| Supply voltage | 10 V DC … 30 V DC |
| Ripple | ≤ 10 % |
| Voltage drop | ≤ 2 V 1) |
| Hysteresis | 3 % … 20 % |
| Reproducibility | ≤ 2 % 2) 3) |
| Temperature drift (of S r ) | ± 10 % |
| Electromagnetic compatibility | According to EN 60947-5-2 |
| Constant current I a | ≤ 200 mA |
| No load current | ≤ 10 mA |
| Short circuit protection | ✔ |
| Short circuit protection | ✔ |
| Connection pulse protection | ✔ |
| Shock and vibration resistant | 100 g / 2 ms / 500 cycles; 150 g / 1 million cycles; 10 Hz … 55 Hz / 1 mm; 55 Hz … 500 Hz / 60 g |
| Ambient temperature, operation | –40 °C … +100 °C |
| The material of the house | Stainless steel V2A, DIN 1.4305 / AISI 303 |
| Material, active surface | Plast, LCP |
| House length | 65 mm |
| Usable thread length | 47 mm |
| Max. tightening torque | Typ. 60 Nm 4)
Typ. 90 Nm 5) |
| Protection class | III |
| MTTFD | 2,016 years |
| DCavg | 0 % |